Home

Architectural aluminium systems

* restricted access zones
+34 981 804 213

CERTIFICATION CWCT British Standard 




                                                   

Please visualizes the video of the curtain wall testing  for CWCT (Center for Window and Cladding Technology) standard sequence B according to the British Standard for the system Façade TPH-52.

This system overcame the test in the independent UKAS accredited testing laboratory WINTECH ENGINNERING LIMITED n º 2223 located in Telford, United Kingdom .


 


 

Test arrangement:

 

1- Air permeability
P=1200 Pa (158 Km/h = Hurricane F2)

2-Water penetration Static
P=750 Pa (125 Km/h = Hurricane F1)
Water flow  3.4 l/min.m²
Lenght test  55 minutes

3-Wind resistance. Serviceability
Serviceability P=2400 Pa (225 Km/h = Hurricane F4)

4- Air permeability (repetition)
P=1200 Pa (158 Km/h = Hurricane F2)

5- Water penetration Static (repetition)
P=750 Pa (125 Km/h = Hurricane F1)
Water flow 3.4 l/min.m²
Lenght test  55 minutes
6- Water penetration. Dynamic Engine
P=600 Pa (112 Km/h = Hurricane F1)
Water flow 3.4 l/min.m²
Lenght test  15 minutes

7- Water penetration. Dynamic Fan
Pulses of pressures 300-900 Pa (79 – 137 Km/h)
Water flow 3.4 l/min.m²
Lenght test  30 minutes

8- Water penetration. Hose
Lenght test  225 minutes

9- Wind resistance. Safety
P=3600 Pa (273 Km/h = Hurricane F5)
CREATIVITY::AACCENTIA::IMPLEMENTATION